Rack Ground Bars for 19-Inch Racks, Relay Racks & Equipment Cabinets
Rack ground bars provide a common connection point for equipment bonding conductors inside server racks, relay racks and equipment cabinets. The bar is one component of the specified grounding and bonding network; fitting a bar alone does not establish a complete grounding system.
Carsai manufactures custom copper rack ground bars to drawings, with specified dimensions, terminal patterns and bare or tin-plated finishes. Start with the rack layout and the actual cable lugs: a bar can fit the available space yet leave its connections inaccessible.

Choose the Orientation Around the Equipment Layout
Horizontal rack ground bars consolidate connections at one level. Check which rack units or rear mounting positions the assembly occupies, and whether incoming cables can reach it without crossing equipment removal paths. The best position depends on the approved layout, not a universal top, middle or bottom location.
Vertical rack ground bars place connection points at several equipment levels. Specify the actual bar length, mounting locations and terminal distribution rather than ordering only by cabinet height or rack-unit count. Leave room for adjacent PDUs, cable managers and access to connection hardware.
For an open relay rack, identify the exact upright or cross-member used for mounting. A closed cabinet may offer different fixing surfaces and impose door, side-panel or equipment-slide clearances. The term relay rack does not, by itself, specify a higher electrical rating.
Verify the Rack Interface, Not Just the Width Label
A 19-inch or 23-inch rack designation is not a complete manufacturing dimension. Confirm the mounting-hole centres, fixing type, bracket offsets and overall assembly envelope against the particular rack drawing. Do not derive a cut length from the width label alone.
For example, Hammond’s rack and cabinet busbar range separates horizontal rack-mounted products from cabinet-mounted horizontal and vertical versions. Their fixing arrangements are product-specific, not interchangeable mounting instructions for a custom bar.
Show whether the rack has threaded, square or clearance holes at the intended attachment points. Dimension the bar mounting pattern separately from the equipment-lug pattern, and identify any slots and their intended adjustment direction. Include the space occupied by supports and bolt ends, not just the copper strip.
Lay Out Terminals Using the Actual Lugs
A hole count is not a connection count. A two-hole lug needs a matched pair; other holes may be reserved for mounting or the connection to the wider bonding network. Provide lug drawings or part numbers so the palm width, hole size and cable exit direction can be checked together.
Allow space to tighten and inspect each connection after the rack is populated. Keep the required contact area clear of neighbouring lugs, supports and labels. Mark spare connection positions separately so future capacity is not accidentally consumed by mounting hardware.
Define the Contact Arrangement and Kit Contents
Specify the copper grade and required finished condition. If tin plating is required, include the finish specification and any contact-area requirements on the drawing. Do not substitute another conductor material simply because the bar has the same dimensions.
Direct mounting and mounting on insulating supports are different mechanical arrangements. The project design must define the intended bonding connections in either case. Insulating supports do not remove the need for the specified bonding path, and a fixing screw should not be assumed to provide that path without the approved connection detail.
Separate the purchase into the bar, supports and connection accessories. List which brackets, insulators, fasteners, lugs, bonding conductors and identification items are to be supplied, and which are installed by others. Ask for these items to be itemized in the quotation rather than assume that a rack ground bar kit includes every connection.
Where the project requires a listed product or other approval evidence, identify the requirement before sourcing. A custom bar manufactured to a drawing is not automatically equivalent to an approved rack accessory or a tested grounding assembly.
Check a Sample in the Intended Rack
Before releasing repeat quantities, trial-fit the agreed configuration. Check fixing alignment, lug seating, cable routing, tightening access and interference with doors or removable equipment. Confirm the finish and ordered accessories against the drawing and packing list. Mechanical fit checks are separate from the electrical verification required by the project.
For a custom rack ground bar quotation, send the rack model or mounting drawing, bar dimensions and material, lug layout, finish, support arrangement, quantity and required acceptance documents. Include a 2D drawing and a STEP assembly when available. Send the rack layout and bar drawing to Carsai with the requested supply scope so the quotation covers the parts your project actually needs.